Measurement of Optic Nerve and Optic Nerve Sheath Diameter in MRI Brain

Authors

  • Sharma Paudel Department of Radiodiagnosis, Maharajgunj Medical Campus, Tribhuvan University Teaching Hospital, Institute of Medicine, Maharajgunj, Kathmandu, Nepal Author
  • Sweta Joshi Department of Radiodiagnosis, Maharajgunj Medical Campus, Tribhuvan University Teaching Hospital, Institute of Medicine, Maharajgunj, Kathmandu, Nepal Author
  • Durga Pandey Department of Radiodiagnosis, Maharajgunj Medical Campus, Tribhuvan University Teaching Hospital, Institute of Medicine, Maharajgunj, Kathmandu, Nepal Author
  • Prakash Kayastha Department of Radiodiagnosis, Maharajgunj Medical Campus, Tribhuvan University Teaching Hospital, Institute of Medicine, Maharajgunj, Kathmandu, Nepal Author

DOI:

https://doi.org/10.59779/jiomnepal.1277

Keywords:

MRI, optic nerve, optic nerve sheath

Abstract

Introduction: Many diseases affect the size of the optic nerve and optic nerve sheath, measurement of which is important for the diagnosis and treatment of different pathologies of the brain and orbit. This study aimed to measure the diameter of the optic nerve and optic nerve sheath in MRI brain examinations. We also studied their variation according to age, gender, and laterality.

Methods: This cross-sectional, quantitative study was performed in the Radiology Department of Tribhuvan University Teaching Hospital (TUTH). The diameter of the optic nerve and optic nerve sheath were measured in the T2 weighted Dixon Turbo Spin Echo axial images. The diameter was measured at the level of 3mm and 8mm behind the eye globe. The study was completed over a period of 3 months (August 2023 to October 2023).

Results: The mean diameters of the optic nerve were 2.187±0.35 mm/2.14 ± 0.35 mm at 3 mm behind the eye globe and 2.056 ± 0.334 mm/2.11 ± 0.35 mm at 8 mm behind the globe for the right/left sides respectively. The optic nerve sheath of the right/left sides measured 4.50 ± 0.60 mm/4.46 ± 0.56 mm at 3 mm behind the eye globe and 4.16 ± 0.50 mm/ 4.14 ± 0.47 mm at 8mm behind the eyeball.

Conclusion: The measurements for the diameter of the optic nerve and optic nerve sheath complex were similar in both the right and left eyes. There was no significant difference in optic nerve and optic nerve sheath diameters with the age and gender of the participants.

Downloads

Published

2023-12-31

How to Cite

Paudel, S., Joshi, S., Pandey, D., & Kayastha, P. (2023). Measurement of Optic Nerve and Optic Nerve Sheath Diameter in MRI Brain. Journal of Institute of Medicine Nepal, 45(3), 36-41. https://doi.org/10.59779/jiomnepal.1277

Most read articles by the same author(s)

Similar Articles

1-10 of 58

You may also start an advanced similarity search for this article.